Falex-FT2-SAE-环球(香港)科技有限开云
Product
Location:Home > Our Products > Applications > Industrial Lubrication > Falex-FT2-SAE
Product information
Falex-FT2-SAE
Category:Industrial Lubrication
Method Standard:SAE ARP 5996
Application:Evaluation of Coking Propensity of Aviation Lubricants Using the Single Phase Flow Technique.
Brand:FALEX
Description Standard Test Methods Technical Data

The Falex Thermal Fouling Tester (FT2) is the first instrument designed specifically for the SAE ARP 5996 Evaluation of Coking Propensity of Aviation Lubricants Using the Single Phase Flow Technique.

The FT2 is the ultimate in ease of operation and provides user flexible programmability with extensive customizable safety and shutdown protocols. The FT2’s enhanced hotspot determination and profile automation routines assure the highest precision for your critical turbine oil analysis laboratory.

A lubricant sample is passed over a pressurized, tube-in-shell heat exchanger for a set time period. The specimen tube, made of 316 stainless steel, is weighed before and after the test to determine the amount of coking propensity exhibited by the test lubricant.

 

»» An integrated Peltier cooling system saves valuable bench space and provides consistent cooling temperatures for each test

»» Automatic tube temperature profiles reduce operator time and improve test precision

»» A redundant safety system keeps the unit self-sufficient in case of leak, mishap or power outage

»» High-Speed data acquisition of all critical thermocouples and system outputs

»» Hermetically-sealed gear pump for leak-free longevity and pulse-dampened flow

»» Customizable test parameters for additional points of research


SAE ARP 5996  Evaluation of Coking Propensity of Aviation Lubricants Using the Single Phase Flow Technique


Operation

Sample volume

100 mL to 1 L

Tube temperature range

300 °C to 450 °C

Heated reservoir range

100 °C to 210°C

Units of temperature

°C, °F

Fluid flow rate

0.55 to 10 mL/min

Test duration

2.5 to 500 hours

Pressure

0 to 200 psi

Units of pressure

kPa, PSI

Data Management

Display

Real time on screen trend data

Results download

Hot spot profile, Test data

File type

.csv

Interface

User Interface

12” LCD can be used with gloves, USB, keyboard and mouse

Data input/output

USB (5), Ethernet (2)

Printer options

USB, Ethernet

Calibration

Temperature

2-point temperature calibration

Pressure

2-point pressure calibration

Power Requirements

Voltage x 2

115V 60Hz or 230V 50/60 Hz

Plug Type

1 NEMA 5-20 or NEMA 6-15

Utility Requirments

Pressure

Nitrogen or Air

Physical

Dimensions

30” x 30” x 22”

Weight

175 lbs. (without options)